Thông tin sản phẩm
Operating temperature/humidity: 0 to 50°C/10 to 90% RH (no freezing or condensation)
Rated input voltage: DC24V±10%
Output variable range (rms) at no load: AC output 4kV / DC output -150 to +550V
Secondary short circuit current: 5mA or less
Output monitor: 1/1000V±5% of the output voltage is output to the monitor terminal
Storage temperature/humidity: -30 to 70°C/10 to 90% RH (no freezing or condensation)
Low voltage detection: When the output voltage falls below 85% of the set voltage due to high voltage shortening or abnormal sparks, an abnormality is detected.
Power input connector: Molex 5569-04A1-210
High voltage output connector: Ceramic high voltage output terminal (2 pieces)
Alarm output terminal: C contact relay output
Power supply (V): DC24±10%
Width(mm):102.8
Depth (mm): 114.2
Height (mm): 233.5
VESSEL GP-1 4KV